CA‐NETProtocol
page6/33
<ErrorID>isanumericalvalueforanerrorcode.
“<Error Description>” is a text chain inside double quotation marks, containing an error
description.
DAM514NOTES:
<RemoteMode>parameter
OriginallydesignedtoconnectWPmVOL‐SR(orWPTOUCH)wallpanelstotheREMOTEports
in the DAM514: panels that include a volume control knb and a 5‐position selector knob.
The possibleworking modes (REMOTE_MODE command)of any of the 4 available remote
ports(R1toR4)intheunitare:
o DISABLED
o IN_VOL:volumecontrolforoneorseveralinputs(generalinputvolume,affectingall
thepostprocessing)
o ZONE_VOL:volumecontrolforoneorseveralzoneoutputs
o IN_SEL: one input (source) selection for one or several output zones (with the 5
positionselector)
o IN_SEL_IN_LEVEL:oneinput(source)selectionforoneorseveraloutputzones(with
the5positionselector)+thecontroloftheselectedinput’scrosspointsleveltothe
destinationzones
o IN_SEL_ZONE_VOL: one input (source) selection for one or several output zones
(withthe5positionselector)+thecontroloftheaffectedzonesoutputvolume
o PRESET:apresetrecovery,fromP1toP5(withthe5positionselector)
o PRESET_ZONE_VOL:apresetrecovery,fromP1toP5(withthe5positionselector)+
volumecontrolforoneorseveralzoneoutputs
PAGER/DUCKERparameterforTALKOVER_MODEcommand:
o INPUT 5
can be used with the Talkover feature in PAGER or DUCKER mode. PAGER
moderequiresanexternalpagingstation (MPAGE4)to select thedestination zones
andperformingthepaging
o INPUT4canbeusedwiththeTalkoverfeaturejustinDUCKERmode